General Information
The А1220 is designed for inspecting reinforced concrete (as well as rocks, plastics and similar materials) for foreign inclusion, voids and cracks. The flaw detector may be used for thickness measurements and the investigations of internal structures, estimation of thickness of asphalt coverings of roads, and physico-mechanical properties of composites and plastic.
 
Flaw detector A1220 consists of an electronic unit with built-in LCD screen and soft keyboard, 24 (6 x 4) elements antenna array (AA), additional ultrasonic probes of longitudinal and shear waves. AA is used in the echo - method testing.
 
Damped low-frequency ultrasonic probes with dry point contact are located in a 6x4 matrix. Each element has independent spring loading Monitoring procedure without couplants due to design of the AA, and product surfaces can have curvature radius from 150 mm and more, and roughness up to 8 mm. Additional ultrasonic probes are used for pulse echo testing, in a transducer similar to AA elements do not require couplants.
 
Special Features
Range ultrasound frequency operating 20 - 150 kHz;
Echo - pulse and shadow methods testing with use of longitudinal, shear and surface waves;
Dry acoustic contact to material surface;
1D and 2D presentation of echo - signals on the LCD screen;
Selections of weak signals on the background noise by accumulation methods.
Automatic and manual operation modes for detection of flaw coordinates or object' thickness;
Automatic and manual ultrasonic velocity measuring in material;
Parameters adjustments with help of menu options, saving of settings library;
Screen illuminations, self contained power supply, automatic power supply switch off;
Recording results in the device permanent memory and their viewing on the screen with measurements via the help of screen cursors;
Data transferring on the infra red port to the external computer;
3D presentation of internal material structure on the screen of external computer; ·
Teamwork of the device with a computer in real time with the expanded opportunities of the analysis of the form of signals, measurements of their parameters and data recording.
 
Technical Specifications
Depth limits for echo-method testing, mm 75, 150, 375, 750, 1500
and sweep duration, mcs 75, 150, 375, 750, 1500
Min diameter of detected defects in concrete * on depths up to 500 mm
- air cylinder like 12mm
- air sphere like 50 mm
Max measured thickness of concrete object * 700 mm
The accuracy of defect location depth measurement * +- 10%
Power supply 4 AA batteries
Time of continuous work without battery replacement:  
 with screen illumination not less than 15 hours;
 without screen illumination not less than 50 hours
Operating temperatures range from -20C to +45C
Dimensions of electronic unit 235 x 98 x 33 mm
Weight of electronic unit 800 g
Weight of AA batteries 760 g
 
 